HOMEABOUT USCONTACT USSITE MAP  CELEBRATING OVER 25 YEARS SERVICE TO THE INDUSTRY
DIY POOL KITSPROFESSIONAL POOL KITSABOVE GROUND POOLSFLOORING SUN DOMES  
LINKSAUTOMATIC CLEANER  SAFETY COVERSSOLAR HEATINGPOOL EQUIPMENTTOYS & GAMESINFLATABLES

Heat Pumps

What Size? What Price?

Normally, heat pumps are sold for use in the summer season only. Yes, all the manufacturers state that they will work in ambient temperatures from 0-5 deg but will have minimal heat output, and realistically, at these temperatures you will be unlikely want to be swimming. Ideally, a heat pump should not be switched on until the ambient air temperature has reached 15-20 deg.C

Heat pumps are ideally suited for heating your pool in the summer season only (May – September). However, with various climate changes that we have been experiencing in recent years, we have had reports from our customers that they have been running their heat pumps from April to late October!

Unfortunately, sizing the heat for your swimming pool is not an exact science due to so many variables such as the thermal value of the pool structure, wind speed, water velocity, water table etc and if a heat retention cover has been applied.

Therefore, heat pump manufacturers base their calculations on the amount of heat (kW) your pool is likely to loose on an hourly basis. You will see that on some pool sizes we recommend two sizes of heater. If your budget allows, it is desirable to buy the larger size, due to it being more cost effective, efficient thus resulting is a quicker heat up time.

The sizing chart below assumes the following:-

• 15 deg C / 59F ambient air temperature (Realistic for start of season)

• Average wind speed 2.5 metres per second

• Desired water temperature 30 deg c / 86F

• Average pool depth 1.5m / 5ft

• No water table surrounding pool structure

• Minimum running time 10 hours per day

In the event that you are not able to meet the above criteria or for a more detailed analysis on heat loss or to size another pool please use the online guide www.paramountpoolsonlineguide.co.uk Here you will be able to access the ‘Swimming Pool Heat Loss Calculator’.

POOL SIZE -IMPERIAL POOL SIZE - METRIC Heater
Lenght ft Width ft Appox Gallons Length M Width M Approx Litres Minimum size heater required KW Optimum size heater required KW
24 12 8550 7.32 3.66 38868 9 14
26 13 10034 7.92 3.96 45616 9 14
28 14 11638 8.53 4.27 52904 14 14
30 15 13359 9.14 4.57 60732 14 29
32 16 15200 9.75 4.88 69099 29 29
36 18 19238 10.97 5.49 87454 29 29
40 20 23750 12.19 6.10 107968 29 29

Please do not be misguided by high COP claims from other manufactures. Many of these claims are based on ambient air temperatures of 25 degC / 77F
which we feel are unrealistic at the beginning of the season

RA
Range
Code Output BTU Price Delivery
68150-N 9kw 30,000 £1,225.00+VAT
£63.83+VAT
RA DELUXE
Range
68010-N 14kw 50,000 £1,853.83+VAT £63.83+VAT
68120-N 29kw 99,000 £3,160.63+VAT £63.83+VAT
RA Through
wall ducting ki
t
CK30000-N 9-14KW £170.66+VAT
CK30001-N 29KW £216.24+VAT

To download the manual click here